Medical Imaging & Technology Alliance (MITA) is a lobby for equipment manufacturers of medical imaging machinery. ==Standards== MITA is also the source of the DICOM standard and the XR series of medical imaging and radiation dose standards: XR 26-2012 ''Access Controls for Computer Tomography: Identification, Interlocks, and Logs'' XR 27-2012 ''User QC Standard'' XR 24-2008 ''Primary User Controls for Interventional Angiography X-Ray Equipment'' XR 23-2006 ''Quality Control Manual Template for Manufacturers of Hardcopy Output Devices Labeled for Final Interpretation in Full-Field Digital mammography'' (FFDM) XR 22-2006 ''Quality Control Manual Template for Manufacturers of Displays and Workstations Labeled for Final Interpretation in Full-Field Digital Mammography'' (FFDM) XR 21-2000 ''Characteristics of and Test Procedures for a Phantom to Benchmark Cardiac Fluoroscopic and Photographic Performance'' XR 19-1993 (R1999) ''Electrical, Thermal and Loading Characteristics of X-Ray Tubes Used for Medical Diagnosis'' XR 18-1993 (R1999) ''Test Standard for the Determination of the Radial Image Distortion of an X-ray image intensifier (XRII) System'' XR 17-1993 (R1999) ''Test Standard for the Measurement of the Image Signal Uniformity of an X-Ray Image Intensifier (XRII) System'' XR 16-1991 (R1996, R2001) ''Test Standard for the Determination of the System Contrast Ratio (SCR) and the System Veiling Glare Index'' (SVGI) ''of an X-Ray Image Intensifier'' (XRII) ''System'' XR 15-1991 (R1996, R2001) ''Test Standard for the Determination of the Visible Entrance Field Size of an X-Ray Image Intensifier'' (XRII) ''System'' XR 14-1990 (R1995, R2000) ''Recommended Practices for Load-Bearing Mechanical Assemblies Used in Diagnostic Imaging'' NEMA XR 13-1990 (R1995, R2000) ''Mechanical Safety Standard for Power Driven Motions of Electromedical Equipment'' XR 11-1993 (R1999) ''Test Standard for the Determination of the Limiting Spatial Resolution of X-Ray Image Intensifier Systems'' XR 10-1986 (R1992, R1998, R2003) ''Measurement of the Maximum Symmetrical Radiation Field from a Rotating Anode X-Ray Tube Used for Medical Diagnosis'' XR 9-1984 (R1994, R2000) ''Power Supply Guidelines for X-Ray Machines'' XR 7-1995 (R2000) ''Electrical, Thermal and Loading Characteristics of X-Ray Tubes Used for Medical Diagnosis'' XR 5-1992 (R1999) ''Measurement of Dimensions and Properties of Focal Spots of Diagnostic X-Ray Tubes'' 抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)』 ■ウィキペディアで「Medical Imaging and Technology Alliance」の詳細全文を読む スポンサード リンク
|